Ex-proof wall-mounted biogas analysis system TY-6090EX
Ex-proof wall-mounted biogas analysis system TY-6090EX measures CH4,CO2,O2,H2S optional CO and H2 at the same time in one unit. It adopts modularization sensor design, easy for replacement and maintenance.
Enquiry now
Product Details Specifications User's guidance After-sales support

I. Introduction

Ex-proof wall-mounted biogas analysis system TY-6090EX measures CH4,CO2,O2,H2S optional CO and H2 at the same time in one unit. It adopts modularization sensor design, easy for replacement and maintenance.

 
II. Features

•       Using 10'' TFT LCD touch screen

•       Measurement value display/real-time curve display

•       Calibration menu and alarm setting with password protection

•       One set back to factory setting

•       Integrated zeroing pump for automatically air zeroing

•       PLC control sampling and drainage interval time

•       Stainless steel enclosure for anti-corrosion

•       Optional sampling pump

•       Maximum for six sampling point switching in one unit

 

III. Specifications

Measurement

CH4, CO2, O2, H2S (extendable to CO,H2)

Technology

CH4 , CO2: proprietary dual beam NDIR detectors

O2 ,H2S: industrial electrochemical cell

Ranges

CH4: 0-100%, CO2 : 0-50%, O2: 0-25%, H2S:0-9999ppm

Other ranges customizable on request without price increase

Resolution

0,01% for CH4, CO2, O2; 1ppm for H2S

Accuracy

CO2/CH4/O20.01%H2S1ppm

Repeatability

CO2/CH4/H2S/O2:≤1%FS

Gas conditions at analyzer inlet

Flow:0.7L-1.2/min

Pressure:2kPa≤ inlet pressure≤ 50kPa

Quality: No dust, moisture, tar (external safety filter and optional gas washing unit)

Operating conditions

Tamb : -5°C to 50°C / Pamb : 86 to 108 kPa / RH : 0-90% non-condensing

Response time (T90)

≤  15 sec (NDIR)

Communication interface

4-20mA output; RS232/RS485

Power supply

External 110V-220 VAC-50Hz

Dimensions and weight

Gas analyser :800(L) x 600 (H) x 300 (W) mm / ± 60kg 

 

IV. Applications

Landfill

Sewage treatment

Anaerobic digestion

CDM projects

Medium and large size biogas power plant

III. Specifications

Measurement

CH4, CO2, O2, H2S (extendable to CO,H2)

Technology

CH4 , CO2: proprietary dual beam NDIR detectors

O2 ,H2S: industrial electrochemical cell

Ranges

CH4: 0-100%, CO2 : 0-50%, O2: 0-25%, H2S:0-9999ppm

Other ranges customizable on request without price increase

Resolution

0,01% for CH4, CO2, O2; 1ppm for H2S

Accuracy

CO2/CH4/O20.01%H2S1ppm

Repeatability

CO2/CH4/H2S/O2:≤1%FS

Gas conditions at analyzer inlet

Flow:0.7L-1.2/min

Pressure:2kPa≤ inlet pressure≤ 50kPa

Quality: No dust, moisture, tar (external safety filter and optional gas washing unit)

Operating conditions

Tamb : -5°C to 50°C / Pamb : 86 to 108 kPa / RH : 0-90% non-condensing

Response time (T90)

  15 sec (NDIR)

Communication interface

4-20mA output; RS232/RS485

Power supply

External 110V-220 VAC-50Hz

Dimensions and weight

Gas analyser :800(L) x 600 (H) x 300 (W) mm / ± 60kg 

IV. Applications

Landfill

Sewage treatment

Anaerobic digestion

CDM projects

Medium and large size biogas power plant

Online time: From 9:00 am -18:00 pm at working days
Tel: +86-27-87955899 
For non-working time:+86-138 7102 2002 
Email:info@tyzkkj.com
Related suggestion
O
N
L
I
N
E