Ex-proof 24-hour online syngas analysis system TY-8330EX consists of online continuous syngas analyser, gas conditioning system, washing system, PLC system, industrial computer system(optional). It can measure CH4,CO2,CO,CnHm,O2 and H2 at the same time in one unit, and calculating heating value in MJ/M3 or Kal/m3. It has water bubbler washing system to remove tar, and gas cooler as well as two precise filters to remove moisture and dust. All the measurement data and system status can be transited the centre control system by 4-20mA, RS485 or PLC system.
• Using 5'' TFT LCD touch screen
• Measurement value display/real-time curve display
• Calibration menu and alarm setting with password protection
• One set back to factory setting
• PLC automatically control sampling, water washing, diagnosis
• Two precise gas filter and gas cooler to remove dust and moisture
• Optional with industrial computer to realize remote data transmission.
Measurement |
CO, CO2, CH4, CnHm, O2, H2 and gas calorific value calculation |
Calculation |
High Heating Value or Low Heating Value in MJ/m3 or kcal/m3 |
Technology |
CO, CO2, CH4, CnHm: proprietary dual beam NDIR detectors O2: industrial electrochemical cell H2: MEMS thermal conductivity detector |
Ranges |
CO/ CO2:/CH4 / H2: 0-100%, CnHm : 0-10%, O2: 0-25% Other ranges customizable on request without price increase |
Resolution |
0,01% |
Accuracy |
CO/CO2/CnHm/CH4:±2%FS;H2/O2:±3%FS |
Repeatability |
≤ 1% |
Gas conditions |
Flow:0.7L-1.2/min, internal gas sampling pump, external flow meter with needle valve Pressure:2kPa≤ inlet pressure≤ 50kPa Quality: No dust, moisture, tar (external safety filter and optional gas washing unit) |
Operating conditions |
Tamb : -5°C to 50°C / Pamb : 86 to 108 kPa / RH : 0-90% non-condensing |
Response time (T90) |
≤ 15 sec (NDIR) |
Communication interface |
4-20mA; RS232/RS485 |
Power supply |
External 11V-220 VAC-50Hz |
Dimensions and weight |
Gas analysis system :1800(L) x 800 (H) x 800 (W) mm /200-250kg Water bubble washing system: 1200 (L) x 800 (H) x 300 (W) mm / 75-100kg |
coal chemical process
steel making process as blast furnace, converter, coking, direct iron
ore smelting reduction
syngas production from Biomass and coal gas gasification processes
III. Specifications
Measurement |
CO, CO2, CH4, CnHm, O2, H2 and gas calorific value calculation |
Calculation |
High Heating Value or Low Heating Value in MJ/m3 or kcal/m3 |
Technology |
CO, CO2, CH4, CnHm: proprietary dual beam NDIR detectors O2: industrial electrochemical cell H2: MEMS thermal conductivity detector |
Ranges |
CO/ CO2:/CH4 / H2: 0-100%, CnHm : 0-10%, O2: 0-25% Other ranges customizable on request without price increase |
Resolution |
0,01% |
Accuracy |
CO/CO2/CnHm/CH4:±2%FS;H2/O2:±3%FS |
Repeatability |
≤ 1% |
Gas conditions |
Flow:0.7L-1.2/min, internal gas sampling pump, external flow meter with needle valve Pressure:2kPa≤ inlet pressure≤ 50kPa Quality: No dust, moisture, tar (external safety filter and optional gas washing unit) |
Operating conditions |
Tamb : -5°C to 50°C / Pamb : 86 to 108 kPa / RH : 0-90% non-condensing |
Response time (T90) |
≤ 15 sec (NDIR) |
Communication interface |
4-20mA; RS232/RS485 |
Power supply |
External 11V-220 VAC-50Hz |
Dimensions and weight |
Gas analysis system :1800(L) x 800 (H) x 800 (W) mm /200-250kg Water bubble washing system: 1200 (L) x 800 (H) x 300 (W) mm / 75-100kg |
IV. Applications
coal chemical process
steel making process as blast furnace, converter, coking, direct iron
ore smelting reduction
syngas production from Biomass and coal gas gasification processes