I. Introduction
CEMS continuous emissions monitoring system TY-8310 is a gas analysis product independently developed by the company for environmental monitoring online and industrial online analysis. It can measure SO2, NO, NO2, O2, CO, CO2, dust, temperature, pressure and gas flow. It has the characteristics of high measurement accuracy, strong reliability, low operating cost, fast response time, large span, and wide application range.
Products are widely used in tail gas emission monitoring and process control of coal-fired power plants, garbage power plants, cement plants, glass plants, lime plants, ceramics plants, sintering, coke ovens, desulfurization processes, and denitration processes.
II. Specifications
Measurement |
SO2,NO,NO2,O2 ,CO,CO2 |
Technology |
DOAS or infrared |
Ranges |
Ranges customizable on request without price increase |
Linearity error |
≤1.5%FS |
Repeatability |
≤0.5%FS |
Zero drift |
≤2%FS/7d |
Span drift |
≤2%FS/7d |
Gas conditions at analyzer inlet |
Flow:0.7L-1.2/min Pressure:2kPa≤ inlet pressure≤ 50kPa Quality: No dust, moisture, tar (external safety filter and optional gas washing unit) |
Operating conditions |
Tamb : -10°C to 40°C / Pamb : 86 to 108 kPa / RH : 0-95% non-condensing |
Relay output |
14 channels |
Switch input |
6 channels |
Analog output |
5 channel 4-20mA output |
Analog input |
3 channel 4-20mA input |
Response time (T90) |
≤ 15 sec (NDIR) |
Communication interface |
RS232/RS485 |
Power supply |
External 110V-220 VAC-50Hz |
III. Applications
Products are widely used in tail gas emission monitoring and process control of coal-fired power plants, garbage power plants, cement plants, glass plants, lime plants, ceramics plants, sintering, coke ovens, desulfurization processes, and denitration processes.II. Specifications
Measurement |
SO2,NO,NO2,O2 ,CO,CO2 |
Technology |
DOAS or infrared |
Ranges |
Ranges customizable on request without price increase |
Linearity error |
≤1.5%FS |
Repeatability |
≤0.5%FS |
Zero drift |
≤2%FS/7d |
Span drift |
≤2%FS/7d |
Gas conditions at analyzer inlet |
Flow:0.7L-1.2/min Pressure:2kPa≤ inlet pressure≤ 50kPa Quality: No dust, moisture, tar (external safety filter and optional gas washing unit) |
Operating conditions |
Tamb : -10°C to 40°C / Pamb : 86 to 108 kPa / RH : 0-95% non-condensing |
Relay output |
14 channels |
Switch input |
6 channels |
Analog output |
5 channel 4-20mA output |
Analog input |
3 channel 4-20mA input |
Response time (T90) |
≤ 15 sec (NDIR) |
Communication interface |
RS232/RS485 |
Power supply |
External 110V-220 VAC-50Hz |
III. Applications
Products are widely used in tail gas emission monitoring and process control of coal-fired power plants, garbage power plants, cement plants, glass plants, lime plants, ceramics plants, sintering, coke ovens, desulfurization processes, and denitration processes.