I. Introduction
CEC201 series dual-channel gas condenser is a kind of compressed high efficiency moisture removing, used in gas pretreatment system of gas analysis system. It can protect moisture and corresponding corrosion to the gas analyser and guarantee the lifespan of gas analysers.
II. Specifications
Items |
Descriptions |
Working ambient temperature |
5℃~50℃ |
Inlet gas temperature |
≤180℃ |
Inlet gas dew point |
≤80℃(@ 25℃) |
Outlet gas dew point |
≤4℃(@ 25℃) |
Condensing control temperature |
Factory set at 4.0℃ |
Temperature controller fluctuation |
3.0℃±1.0℃(@ 25℃) |
Condensing method |
fluoride-free compressor |
Gas condensing pipe |
A+B glass heat exchange pipes, diameter * heightΦ40mm*150mm |
Inlet gas pressure |
≤3bar |
Allowed gas differential pressure range |
≤3mbar(gas flow 2NL/min) |
Gas capacity |
250NL/min |
Trouble alarm |
Low temperature alarm, deviation alarm, power off alarm; alarm status dry contact output, capacity 250Vac/1A |
Peristaltic pump *2 pcs |
5r/min, discharge capacity 0.3L/h, left IN and right OUT |
withstand voltage testing standard |
AC1500V |
Leak current |
≤3.5mA |
Inlet gas connector |
OD6mm (OD8mm optional) |
Water drainage port |
OD6mm (OD8mm optional) |
Warming-up time |
≤30min |
Installation method |
Wall-mounted plate installation |
Power supply |
220VAC 50Hz |
Power supply consumption |
400W |
Cabinet size(W×H×D) |
310*280*290mm |
Cabinet color |
RAL7035 grey |
Weight |
18kg |
4-20mA output |
optional |
II. Specifications
Items
Descriptions
Working ambient temperature
5℃~50℃
Inlet gas temperature
≤180℃
Inlet gas dew point
≤80℃(@ 25℃)
Outlet gas dew point
≤4℃(@ 25℃)
Condensing control temperature
Factory set at 4.0℃
Temperature controller fluctuation
3.0℃±1.0℃(@ 25℃)
Condensing method
fluoride-free compressor
Gas condensing pipe
A+B glass heat exchange pipes, diameter * heightΦ40mm*150mm
Inlet gas pressure
≤3bar
Allowed gas differential pressure range
≤3mbar(gas flow 2NL/min)
Gas capacity
250NL/min
Trouble alarm
Low temperature alarm, deviation alarm, power off alarm; alarm status dry contact output, capacity 250Vac/1A
Peristaltic pump *2 pcs
5r/min, discharge capacity 0.3L/h, left IN and right OUT
withstand voltage testing standard
AC1500V
Leak current
≤3.5mA
Inlet gas connector
OD6mm (OD8mm optional)
Water drainage port
OD6mm (OD8mm optional)
Warming-up time
≤30min
Installation method
Wall-mounted plate installation
Power supply
220VAC 50Hz
Power supply consumption
400W
Cabinet size(W×H×D)
310*280*290mm
Cabinet color
RAL7035 grey
Weight
18kg
4-20mA output
optional